Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Clin Cardiol ; 47(3): e24250, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38450791

RESUMO

BACKGROUND: Catheter ablation has become one of the main treatment strategies in patients with premature ventricular complexes (PVC). The successful mapping and ablation can be performed with an ablation catheter without additional diagnostic catheters. HYPOTHESIS: We hypothesize that using a single catheter for PVC ablation may decrease complications, procedure time, and fluoroscopy exposure while maintaining comparable success rates. METHODS: Sixty-nine consecutive patients with PVC were treated with a single catheter approach compared to a historical cohort, in which a conventional setup was used. Propensity score matching was conducted with a 1:1 ratio. Outcome parameters included acute procedural success with elimination of all premature ventricular contractions after catheter ablation, procedural data as well as complication rates. RESULTS: Patients treated with a single catheter approach had shorter total procedure (60 minutes [IQR: 47,5-69,0 minutes] vs. 90 minutes [IQR 60-120 minutes]; p = 0.001) and fluoroscopy times (218 seconds [IQR: 110,5-446 seconds] vs. 310 seconds [IQR 190-640 seconds]; p = 0.012), which consecutively leads to a reduction of radiation exposure signified by a lower dose area product (155 cGycm² [IQR 74.4-334.5 cGycm²] vs. 368.4 cGycm² [IQR: 126-905.4 cGycm²]; p value 0.009). Acute procedural success rates were comparable in both groups (54 [84.3%] in the single catheter approach group and 58 [90.6%] in the conventional group; p: 0.287). CONCLUSION: A single catheter approach for the treatment of PVC is associated with a reduction of procedure- and fluoroscopy time, as well as a lesser radiation exposure, while maintaining equivalent acute success and complication rates compared with a conventionally used catheter setup.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Fluoroscopia , Pontuação de Propensão
2.
Eur Heart J ; 45(13): 1104-1115, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366821

RESUMO

Research performed in Europe has driven cardiovascular device innovation. This includes, but is not limited to, percutaneous coronary intervention, cardiac imaging, transcatheter heart valve implantation, and device therapy of cardiac arrhythmias and heart failure. An important part of future medical progress involves the evolution of medical technology and the ongoing development of artificial intelligence and machine learning. There is a need to foster an environment conducive to medical technology development and validation so that Europe can continue to play a major role in device innovation while providing high standards of safety. This paper summarizes viewpoints on the topic of device innovation in cardiovascular medicine at the European Society of Cardiology Cardiovascular Round Table, a strategic forum for high-level dialogue to discuss issues related to the future of cardiovascular health in Europe. Devices are developed and improved through an iterative process throughout their lifecycle. Early feasibility studies demonstrate proof of concept and help to optimize the design of a device. If successful, this should ideally be followed by randomized clinical trials comparing novel devices vs. accepted standards of care when available and the collection of post-market real-world evidence through registries. Unfortunately, standardized procedures for feasibility studies across various device categories have not yet been implemented in Europe. Cardiovascular imaging can be used to diagnose and characterize patients for interventions to improve procedural results and to monitor devices long term after implantation. Randomized clinical trials often use cardiac imaging-based inclusion criteria, while less frequently trials randomize patients to compare the diagnostic or prognostic value of different modalities. Applications using machine learning are increasingly important, but specific regulatory standards and pathways remain in development in both Europe and the USA. Standards are also needed for smart devices and digital technologies that support device-driven biomonitoring. Changes in device regulation introduced by the European Union aim to improve clinical evidence, transparency, and safety, but they may impact the speed of innovation, access, and availability. Device development programmes including dialogue on unmet needs and advice on study designs must be driven by a community of physicians, trialists, patients, regulators, payers, and industry to ensure that patients have access to innovative care.


Assuntos
Cardiologia , Procedimentos Cirúrgicos Torácicos , Humanos , Inteligência Artificial , Diagnóstico por Imagem , Técnicas de Imagem Cardíaca
3.
Heliyon ; 9(11): e21268, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37954289

RESUMO

Background: Subpopulations of myocardial c-kitpos cells have the ability to stimulate regeneration in ischemic heart disease by paracrine effects. The left atrial appendage (LAA), which is easy accessible during cardiac surgery, may represent a perfect source for c-kitpos cell extraction for autologous cell therapies in the living human. So far, frequency and distribution of c-kitpos cells in LAA are unknown. Methods: LAAs of patients who underwent cardiac surgery due to coronary artery disease (coronary artery bypass graft, CABG), valvular heart disease or both and of two body donors were examined. Tissue was fixed in 4 % paraformaldehyde, embedded in paraffin, dissected in consecutive sections and stained for c-kitpos cells. In parallel, grade of fibrosis, amount of fat per section and cells positive for mast cell tryptase were examined. Results: We collected 27 LAAs (37.0 % female, mean left ventricular ejection fraction 50.4 %, 63.0 % persistent atrial fibrillation (AF)). Most of the patients underwent combined CABG and valve surgery (51.9 %). C-kitpos cells were detected in 3 different regions: A) Attached to the epicardial fat layer, B) close to vascular structures and C) between cardiomyocytes. C-kitpos cells ranged from 0.05 c-kitpos cells per mm2 to 67.5 c-kitpos cells per mm2. We found no association between number of c-kitpos cells and type of AF, amount of fibrosis or amount of fat. Up to 72 % of c-kitpos cells also showed a positive staining for mast cell tryptase. Conclusion: C-kitpos cells are frequent in LAAs of cardiovascular patients with a rather homogenous distribution throughout the LAA. The LAA can therefore be considered as a source for extraction of a reasonable quantity of autologous cardiac progenitor cells in the living human patient.

4.
Europace ; 25(4): 1284-1295, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36879464

RESUMO

The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Estudos Prospectivos , Arritmias Cardíacas , Ventrículos do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
5.
J Am Heart Assoc ; 12(6): e027971, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36892055

RESUMO

Cardiac sarcoidosis can mimic any cardiomyopathy in different stages. Noncaseating granulomatous inflammation can be missed, because of the nonhomogeneous distribution in the heart. The current diagnostic criteria show discrepancies and are partly nonspecific and insensitive. Besides the diagnostic pitfalls, there are controversies in the understanding of the causes, genetic and environmental background, and the natural evolution of the disease. Here, we review the current pathophysiological aspects and gaps that are relevant for future cardiac sarcoidosis diagnostics and research.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Miocardite/diagnóstico , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Cardiomiopatias/terapia , Sarcoidose/diagnóstico , Sarcoidose/terapia , Sarcoidose/complicações , Coração
6.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38193546

RESUMO

AIMS: Ongoing clinical trials investigate the therapeutic value of stereotactic cardiac radioablation (cRA) in heart failure patients with ventricular tachycardia. Animal data indicate an effect on local cardiac conduction properties. However, the exact mechanism of cRA in patients remains elusive. Aim of the current study was to investigate in vivo and in vitro myocardial properties in heart failure and ventricular tachycardia upon cRA. METHODS AND RESULTS: High-density 3D electroanatomic mapping in sinus rhythm was performed in a patient with a left ventricular assist device and repeated ventricular tachycardia episodes upon several catheter-based endocardial radio-frequency ablation attempts. Subsequent to electroanatomic mapping and cRA of the left ventricular septum, two additional high-density electroanatomic maps were obtained at 2- and 4-month post-cRA. Myocardial tissue samples were collected from the left ventricular septum during 4-month post-cRA from the irradiated and borderzone regions. In addition, we performed molecular biology and mitochondrial density measurements of tissue and isolated cardiomyocytes. Local voltage was altered in the irradiated region of the left ventricular septum during follow-up. No change of local voltage was observed in the control (i.e. borderzone) region upon irradiation. Interestingly, local activation time was significantly shortened upon irradiation (2-month post-cRA), a process that was reversible (4-month post-cRA). Molecular biology unveiled an increased expression of voltage-dependent sodium channels in the irradiated region as compared with the borderzone, while Connexin43 and transforming growth factor beta were unchanged (4-month post-cRA). Moreover, mitochondrial density was decreased in the irradiated region as compared with the borderzone. CONCLUSION: Our study supports the notion of transiently altered cardiac conduction potentially related to structural and functional cellular changes as an underlying mechanism of cRA in patients with ventricular tachycardia.


Assuntos
Ablação por Cateter , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Miócitos Cardíacos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Arritmias Cardíacas , Ablação por Cateter/métodos
7.
Europace ; 24(11): 1800-1808, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851396

RESUMO

AIM: Cardiac sympathetic denervation (CSD) has been introduced as a bailout therapy in patients with structural heart disease and refractory ventricular arrhythmias (VAs), but available data are scarce. Purpose of this study was to estimate immediate results, complications, and mid-term outcomes of CSD following recurrent VA after catheter ablation. METHODS AND RESULTS: Adult patients who underwent CSD in the Heart Center Leipzig from March 2017 to February 2021 were retrospectively analysed. Follow-up (FU) was executed via implantable cardioverter defibrillator (ICD) interrogation, telephone interviews, and reviewing medical records. Twenty-one patients (age 63.7 ± 14.4 years, all men, 71.4% non-ischaemic cardiomyopathy, left ventricular ejection fraction 31.6 ± 12.6%) received CSD via video-assisted thoracoscopic surgery (90.5% bilateral, 9.5% left-sided only). Indication for CSD was monomorphic ventricular tachycardia in 76.2% and ventricular fibrillation in 23.8 with 71.4% of patients presenting with electrical storm before index hospitalization. Procedure-related major complications occurred in 9.5% of patients. In-hospital adverse events not related to surgery were common (28.6%) and two patients died during the index hospital stay. During FU (mean duration 9.1 ± 6.5 months), five more patients died. Of the remaining patients, 38.5 and 76.9% were free from any VA or ICD shocks, respectively. CONCLUSIONS: The CSD showed additional moderate efficacy to suppress VAs, when performed as a bailout therapy after previously unsuccessful catheter ablation. At 9 months, it was associated with freedom of ICD shocks in two-thirds of patients. In a population with many comorbidities, the rate of CSD-related complications was acceptable, although there was an overall high risk of procedure unrelated adverse events and death.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Simpatectomia/efeitos adversos , Simpatectomia/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/cirurgia
8.
JAMA ; 327(23): 2296-2305, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35727277

RESUMO

Importance: Ablation of persistent atrial fibrillation (AF) remains a challenge. Left atrial fibrosis plays an important role in the pathophysiology of AF and has been associated with poor procedural outcomes. Objective: To investigate the efficacy and adverse events of targeting atrial fibrosis detected on magnetic resonance imaging (MRI) in reducing atrial arrhythmia recurrence in persistent AF. Design, Setting, and Participants: The Efficacy of Delayed Enhancement-MRI-Guided Fibrosis Ablation vs Conventional Catheter Ablation of Atrial Fibrillation trial was an investigator-initiated, multicenter, randomized clinical trial involving 44 academic and nonacademic centers in 10 countries. A total of 843 patients with symptomatic or asymptomatic persistent AF and undergoing AF ablation were enrolled from July 2016 to January 2020, with follow-up through February 19, 2021. Interventions: Patients with persistent AF were randomly assigned to pulmonary vein isolation (PVI) plus MRI-guided atrial fibrosis ablation (421 patients) or PVI alone (422 patients). Delayed-enhancement MRI was performed in both groups before the ablation procedure to assess baseline atrial fibrosis and at 3 months postablation to assess for ablation scar. Main Outcomes and Measures: The primary end point was time to first atrial arrhythmia recurrence after a 90-day blanking period postablation. The primary safety composite outcome was defined by the occurrence of 1 or more of the following events within 30 days postablation: stroke, PV stenosis, bleeding, heart failure, or death. Results: Among 843 patients who were randomized (mean age 62.7 years; 178 [21.1%] women), 815 (96.9%) completed the 90-day blanking period and contributed to the efficacy analyses. There was no significant difference in atrial arrhythmia recurrence between groups (fibrosis-guided ablation plus PVI patients, 175 [43.0%] vs PVI-only patients, 188 [46.1%]; hazard ratio [HR], 0.95 [95% CI, 0.77-1.17]; P = .63). Patients in the fibrosis-guided ablation plus PVI group experienced a higher rate of safety outcomes (9 [2.2%] vs 0 in PVI group; P = .001). Six patients (1.5%) in the fibrosis-guided ablation plus PVI group had an ischemic stroke compared with none in PVI-only group. Two deaths occurred in the fibrosis-guided ablation plus PVI group, and the first one was possibly related to the procedure. Conclusions and Relevance: Among patients with persistent AF, MRI-guided fibrosis ablation plus PVI, compared with PVI catheter ablation only, resulted in no significant difference in atrial arrhythmia recurrence. Findings do not support the use of MRI-guided fibrosis ablation for the treatment of persistent AF. Trial Registration: ClinicalTrials.gov Identifier: NCT02529319.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Fibrose , Átrios do Coração , Imageamento por Ressonância Magnética , Cirurgia Assistida por Computador , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Fibrose/diagnóstico por imagem , Fibrose/cirurgia , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
9.
Int J Cardiol Heart Vasc ; 38: 100939, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35024429

RESUMO

INTRODUCTION: Preprocedural cardiovascular magnetic resonance (CMR) or computed tomography (CT) imaging of the left atrium/pulmonary veins is usually employed to guide catheter ablation of atrial fibrillation (AFCA). Incidental findings (IFs) are common on cardiac imaging prior to AFCA. However, previous studies have mainly focused on extracardiac IFs detected on CT scan. We aimed to assess the prevalence of relevant cardiac and extracardiac IFs on routine preprocedural CMR in a large patient cohort scheduled for first-time AFCA and report its impact on clinical decision-making and management. METHODS AND RESULTS: We included 2000 consecutive patients (62 ± 10 years; 59% male) who underwent CMR prior to first-time AFCA between April 2015 and March 2019. Among these patients 172 (8.6%) had a total of 184 major IFs. Detection of major IFs resulted in cancellation of the scheduled AFCA procedure in 88 patients (4.4%). Forty-two patients (2.1%) have never been ablated, 46 (2.3%) underwent postponed AFCA after a median time of 83 (32-213) days. The remaining 84 patients (4.2%) underwent an individualized approach to AFCA. The most common major IFs were accessory or anomalous PVs in 76 (3.8%), extracardiac abnormalities suspicious of malignancy in 29 (1.5%), and positive stress perfusion imaging in 19 (7.2% of 261 tested) patients. In 19 patients (1.0%) preprocedural CMR provided the diagnosis of a previously unknown structural cardiac disease. CONCLUSIONS: Unexpected relevant findings on routine preprocedural CMR affected clinical decision-making and management in 8.6% of patients scheduled for first-time AFCA. However, whether preprocedural CMR imaging may improve overall clinical outcome needs to be addressed in future research.

10.
Clin Res Cardiol ; 111(9): 1028-1039, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34932171

RESUMO

BACKGROUND: Left atrial (LA) reservoir strain provides prognostic information in patients with and without heart failure (HF), but might be altered by atrial fibrillation (AF). The aim of the current study was to investigate changes of LA deformation in patients undergoing cardioversion (CV) for first-time diagnosis of AF. METHODS AND RESULTS: We performed 3D-echocardiography and strain analysis before CV (Baseline), after 25 ± 10 days (FU-1) and after 190 ± 20 days (FU-2). LA volumes, reservoir, conduit and active function were measured. In total, 51 patients were included of whom 35 were in SR at FU-1 (12 HF and preserved ejection fraction (HFpEF)), while 16 had ongoing recurrence of AF (9 HFpEF). LA maximum volume was unaffected by cardioversion (Baseline vs. FU-2: 41 ± 11 vs 40 ± 10 ml/m2; p = 0.85). Restored SR led to a significant increase in LA reservoir strain (Baseline vs FU-1: 12.9 ± 6.8 vs 24.6 ± 9.4, p < 0.0001), mediated by restored LA active strain (SR group Baseline vs. FU-1: 0 ± 0 vs. 12.3 ± 5.3%, p < 0.0001), while LA conduit strain remained unchanged (Baseline vs. FU-1: 12.9 ± 6.8 vs 13.1 ± 6.2, p = 0.78). Age-controlled LA active strain remained the only significant predictor of LA reservoir strain on multivariable analysis (ß 1.2, CI 1.04-1.4, p < 0.0001). HFpEF patients exhibited a significant increase in LA active (8.2 ± 4.3 vs 12.2 ± 6.6%, p = 0.004) and reservoir strain (18.3 ± 5.7 vs. 22.8 ± 8.8, p = 0.04) between FU-1 and FU-2, associated with improved LV filling (r = 0.77, p = 0.005). CONCLUSION: Reestablished SR improves LA reservoir strain by restoring LA active strain. Despite prolonged atrial stunning following CV, preserved SR might be of hemodynamic and prognostic benefit in HFpEF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Função do Átrio Esquerdo , Cardioversão Elétrica/métodos , Átrios do Coração/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico
11.
Circ Arrhythm Electrophysiol ; 15(1): e010168, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34964367

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a novel form of ablation using electrical fields to ablate cardiac tissue. There are only limited data assessing the feasibility and safety of this type of ablation in humans. METHODS: PULSED AF (Pulsed Field Ablation to Irreversibly Electroporate Tissue and Treat AF; https://www.clinicaltrials.gov; unique identifier: NCT04198701) is a nonrandomized, prospective, multicenter, global, premarket clinical study. The first-in-human pilot phase evaluated the feasibility and efficacy of pulmonary vein isolation using a novel PFA system delivering bipolar, biphasic electrical fields through a circular multielectrode array catheter (PulseSelect; Medtronic, Inc). Thirty-eight patients with paroxysmal or persistent atrial fibrillation were treated in 6 centers in Australia, Canada, the United States, and the Netherlands. The primary outcomes were ability to achieve acute pulmonary vein isolation intraprocedurally and safety at 30 days. RESULTS: Acute electrical isolation was achieved in 100% of pulmonary veins (n=152) in the 38 patients. Skin-to-skin procedure time was 160±91 minutes, left atrial dwell time was 82±35 minutes, and fluoroscopy time was 28±9 minutes. No serious adverse events related to the PFA system occurred in the 30-day follow-up including phrenic nerve injury, esophageal injury, stroke, or death. CONCLUSIONS: In this first-in-human clinical study, 100% pulmonary vein isolation was achieved using only PFA with no PFA system-related serious adverse events. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Austrália , Canadá , Ablação por Cateter/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Duração da Cirurgia , Projetos Piloto , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
12.
Heart Vessels ; 37(1): 161-171, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34459957

RESUMO

High-density lipoprotein (HDL), best known for cholesterol transport, also has anti-inflammatory effects. Previous studies suggest involvement of myeloperoxidase (MPO) in modification of HDL. HDL bound Sphingosine-1-phosphate (S1P) has been implied to be an essential protein regarding beneficial HDL effects. In this study, we analyzed anti-inflammatory HDL properties in patients with atrial fibrillation (AF), a disease involving atrial inflammation, compared to non-AF controls and whether anti-inflammatory properties improve upon catheter ablation. Additionally, association with serum concentrations of MPO and S1P were assessed. We isolated HDL from 25 AF patients, 13 non-AF individuals and 14 AF patients at follow-up (FU) after catheter ablation. S1P was measured in a cohort of 141 AF and 21 FU patients. Following preincubation with HDL from either group, bovine aortic endothelial cells were stimulated using tumor necrosis factor α and expression of pro-inflammatory genes intercellular adhesion molecule 1 (ICAM1), vascular cell adhesion molecule 1 (VCAM1), E-selectin (SELE) and P-selectin (SELP) was assessed using qPCR. Concentrations of circulating protein of these genes as well as MPO and S1P were measured in serum samples. Compared to non-AF individuals HDL from AF patients suppressed gene expression of the pro-inflammatory adhesion molecules ICAM1, VCAM1, SELE and SELP 27%, 18%, 21% and 57% less, respectively (p < 0.05 for all except SELE p = 0.06). In FU patients, the anti-inflammatory HDL activity was improved (suppression of ICAM1 + 22%, VCAM1 + 10%, SELE + 38% and SELP + 75%, p < 0.05 for all except VCAM1 p = 0.08). AF patients using angiotensin converting enzyme inhibitors or angiotensin receptor blockers had better anti-inflammatory HDL properties than non-users (gene expression suppression at least 28% more, p < 0.05 for all except ICAM1 p = 0.051). Circulating protein concentrations were not correlated with in vitro gene-expression, but circulating P-selectin was generally elevated in AF and FU patients compared to non-AF patients. MPO plasma concentration was positively associated with gene-expression of ICAM1, VCAM1 and SELP (r2 > 0.4, p < 0.05). Serum concentrations of S1P were increased in FU patients {1.201 µM [1.077-1.543]} compared to AF patients {0.953 µM [0.807-1.135], p < 0.01} but not correlated with ICAM1, VCAM1 and SELP gene expression. We conclude that the anti-inflammatory activity of HDL is impaired in AF patients, which might promote AF progression and AF-associated complications.


Assuntos
Fibrilação Atrial , Animais , Anti-Inflamatórios , Bovinos , Células Endoteliais , Humanos , Lipoproteínas HDL , Selectina-P , Molécula 1 de Adesão de Célula Vascular
14.
Herz ; 46(4): 323-328, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34223913

RESUMO

Anticoagulation in patients with atrial fibrillation (AF) should be guided by considerations of the risk of thromboembolism, stroke, and bleeding as well as the patient's preference. Well-recognized scores have been developed to help the clinician in daily risk assessment, but there are several special patient populations for whom scores are not developed or validated. Furthermore, these patients were not adequately represented in the pivotal randomized trials for non-vitamin K antagonist oral anticoagulants (NOACs). In patients with cancer, the intrinsic hypercoagulable state has to be balanced against an increased risk of bleeding, and a dynamic concept should be applied, taking into account the cancer type, current disease state, therapeutic strategy, and patient-related factors, with NOACs playing an increasingly larger role. In women with planned pregnancy or already pregnant, NOACs should be avoided. However, accidental exposure during pregnancy should not lead to recommendations for pregnancy termination in view of current observational data. Whether patients on dialysis with AF benefit from anticoagulation at all is questionable. But if the decision for anticoagulation is made, NOACs may contribute to a more favorable risk-benefit profile than vitamin- K antagonists. Finally, patients on the ward deserve special considerations regarding periprocedural management of anticoagulation. Although for the majority of procedures a short discontinuation of oral anticoagulation seems appropriate, there are some low-bleeding-risk procedures that do not require cessation. The aim of the present review is to discuss the major particularities of these four patient subgroups and thus to facilitate the clinical decision-making.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Feminino , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
15.
J Cardiovasc Magn Reson ; 23(1): 87, 2021 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-34233708

RESUMO

BACKGROUND: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS: Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS: There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS: In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
16.
Sci Rep ; 11(1): 12411, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127728

RESUMO

Atrial fibrillation (AF) leads to remodeling characterized by changes in both size and shape of the left atrium (LA). Here we aimed to study the effect of hypertrophic cardiomyopathy (HCM) on the pattern of LA remodeling in AF-patients. HCM-patients (n = 23) undergoing AF ablation (2009-2012) were matched and compared with 125 Non-HCM patients from our prospective registry. Pre-procedural CT data were analyzed (EnSite Verismo, SJM, MN) to determine the maximal sagittal (anterior-posterior, AP), coronal (superior-inferior, SI and transversal, TV) dimensions and the sphericity index (LAS). Volume (LAV) was rendered after appendage (LAA) and pulmonary vein (PV) exclusion. A cutting plane, between PV ostia/LAA and parallel to the posterior wall, divided LAV into anterior- (LA-A) and posterior-LA (LA-P) parts. The ratio LA-A/LAV was defined as asymmetry index (ASI). HCM patients had a wider inter-ventricular septum and a smaller LV than Non-HCM patients. LA volume (LAV 166 ± 72 vs. 130 ± 36 ml, p = 0.03) and LA diameters were significantly larger in HCM patients. Anterior volume (LA-A: 112 ± 48 vs. 83 ± 26 ml, p < 0.001) differed significantly between groups, whereas the posterior volume LA-P (55 ± 28 vs. 47 ± 13 ml, p = 0.23) and LAS (75% vs. 78%, p = 0.089) was similar in both groups. As a result, ASI was significantly higher (67 ± 6 vs. 63 ± 6%, p = 0.01) in HCM than in Non-HCM patients. In conclusion, LA remodeling in patients with AF and HCM is characterized by asymmetric dilatation, driven by an anterior rather than a posterior dilatation. This can be characterized by three-dimensional imaging and could be used as surrogate of advanced atrial remodeling.


Assuntos
Fibrilação Atrial/fisiopatologia , Remodelamento Atrial/fisiologia , Cardiomiopatia Hipertrófica/complicações , Átrios do Coração/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/complicações , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo/fisiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/genética , Cardiomiopatia Hipertrófica/fisiopatologia , Ablação por Cateter , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/genética , Hipertrofia Ventricular Esquerda/fisiopatologia , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Prevalência , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Herz ; 46(4): 329-335, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34086059

RESUMO

Atrial fibrillation (AF) will become one of the biggest challenges in cardiovascular medicine in the near future. Attempting an improvement in future patient care calls explicitly for the screening of subclinical AF. Digital health solutions implementing communication technologies for the collection and analysis of digitally assessable data will most likely serve this need. Several new rapidly developing methods were introduced in the past decade. Although the vast majority still require scientific validation, the body of evidence is growing and several randomized controlled trials are planned. This review aims to give an overview of current technologies with a specific focus on mobile health (mHealth) and appraise their value with regard to the available scientific data.


Assuntos
Fibrilação Atrial , Telemedicina , Fibrilação Atrial/diagnóstico , Humanos , Programas de Rastreamento
19.
Int J Cardiol Heart Vasc ; 33: 100730, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33718586

RESUMO

BACKGROUND: Left atrium (LA) remodeling is associated with atrial fibrillation (AF) and reduced success after AF ablation, but its relation with low-voltage areas (LVA) is not known. This study aimed to evaluate the relation between regional LA changes and LVAs in AF patients. METHODS: Pre-interventional CT data of patients (n = 24) with LA-LVA (<0.5 mV) in voltage mapping after AF ablation were analyzed (Surgery Explorer, QuantMD LLC). To quantify asymmetry (ASI = LA-A/LAV) a cutting plane parallel to the rear wall and along the pulmonary veins divided the LA-volume (LAV) into anterior (LA-A) and posterior parts. To quantify sphericity (LAS = 1-R/S), a patient-specific best-fit LA sphere was created. The average radius (R) and the mean deviation (S) from this sphere were calculated. The average local deviation (D) was measured for the roof, posterior, septum, inferior septum, inferior-posterior and lateral walls. RESULTS: The roof, posterior and septal regions had negative local deviations. There was a correlation between roof and septum (r = 0.42, p = 0.04), lateral and inferior-posterior (r = 0.48, p = 0.02) as well as posterior and inferior-septal deviations (r = -0.41, p = 0.046). ASI correlated with septum deformation (r = -0.43, p = 0.04). LAS correlated with dilatation (LAV, r = 0.49, p = 0.02), roof (r = 0.52, p = 0.009) and posterior deformation (r = -0.56, p = 0.005). Extended LVA correlated with local deformation of all LA walls, except the roof and the septum. LVA association with LAV, ASI and LAS did not reach statistical significance. CONCLUSION: Extended LVA correlates with local wall deformations better than other remodeling surrogates. Therefore, their calculation could help predict LVA presence and deserve further evaluation in clinical studies.

20.
PLoS One ; 16(3): e0249251, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33765096

RESUMO

BACKGROUND: During the early phase of the Covid-19 pandemic, reductions of hospital admissions with a focus on emergencies have been observed for several medical and surgical conditions, while trend data during later stages of the pandemic are scarce. Consequently, this study aims to provide up-to-date hospitalization trends for several conditions including cardiovascular, psychiatry, oncology and surgery cases in both the in- and outpatient setting. METHODS AND FINDINGS: Using claims data of 86 Helios hospitals in Germany, consecutive cases with an in- or outpatient hospital admission between March 13, 2020 (the begin of the "protection" stage of the German pandemic plan) and December 10, 2020 (end of study period) were analyzed and compared to a corresponding period covering the same weeks in 2019. Cause-specific hospitalizations were defined based on the primary discharge diagnosis according to International Statistical Classification of Diseases and Related Health Problems (ICD-10) or German procedure classification codes for cardiovascular, oncology, psychiatry and surgery cases. Cumulative hospitalization deficit was computed as the difference between the expected and observed cumulative admission number for every week in the study period, expressed as a percentage of the cumulative expected number. The expected admission number was defined as the weekly average during the control period. A total of 1,493,915 hospital admissions (723,364 during the study and 770,551 during the control period) were included. At the end of the study period, total cumulative hospitalization deficit was -10% [95% confidence interval -10; -10] for cardiovascular and -9% [-10; -9] for surgical cases, higher than -4% [-4; -3] in psychiatry and 4% [4; 4] in oncology cases. The utilization of inpatient care and subsequent hospitalization deficit was similar in trend with some variation in magnitude between cardiovascular (-12% [-13; -12]), psychiatry (-18% [-19; -17]), oncology (-7% [-8; -7]) and surgery cases (-11% [-11; -11]). Similarly, cardiovascular and surgical outpatient cases had a deficit of -5% [-6; -5] and -3% [-4; -3], respectively. This was in contrast to psychiatry (2% [1; 2]) and oncology cases (21% [20; 21]) that had a surplus in the outpatient sector. While in-hospital mortality, was higher during the Covid-19 pandemic in cardiovascular (3.9 vs. 3.5%, OR 1.10 [95% CI 1.06-1.15], P<0.01) and in oncology cases (4.5 vs. 4.3%, OR 1.06 [95% CI 1.01-1.11], P<0.01), it was similar in surgical (0.9 vs. 0.8%, OR 1.06 [95% CI 1.00-1.13], P = 0.07) and in psychiatry cases (0.4 vs. 0.5%, OR 1.01 [95% CI 0.78-1.31], P<0.95). CONCLUSIONS: There have been varying changes in care pathways and in-hospital mortality in different disciplines during the Covid-19 pandemic in Germany. Despite all the inherent and well-known limitations of claims data use, this data may be used for health care surveillance as the pandemic continues worldwide. While this study provides an up-to-date analysis of utilization of hospital care in the largest German hospital network, short- and long-term consequences are unknown and deserve further studies.


Assuntos
Assistência Ambulatorial/tendências , COVID-19/patologia , COVID-19/epidemiologia , COVID-19/virologia , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/patologia , Bases de Dados Factuais , Alemanha/epidemiologia , Mortalidade Hospitalar , Hospitalização/tendências , Hospitais , Humanos , Neoplasias/mortalidade , Neoplasias/patologia , Razão de Chances , Admissão do Paciente/tendências , SARS-CoV-2/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA